Crib page for PiP/TOF 2001 experiments
This web page is a source of information relevant to the PiP/TOF
experiments at the MAMI-B electron beam accelerator at Mainz in 2001.

The setup
The experimental proposal [postscript]
Experimental layout [postscript]
Circuit
diagram of PiP-TOF trigger [postscript]
Circuit
diagram for TOF supplement [postscript]
Circuit
diagram for TAGGER supplement [postscript]
Latest info
Tasks for first PiP/TOF beam time - Jan 24th-28th
Results from test of PiP with cosmics
- July 2001
Shiftworkers crib sheets
The links below give crib sheets for carrying out some standard procedures
expected during run time. To modify the crib sheets copy the HTML file
to your local disk (by right clicking the mouse on the link), then edit
the HTML file. You can do this by either editing the raw HTML file in an
editor (eg Xemacs) or by using a HTML editor (eg. Netscape composer). Then
send the modified file as an attachment to d.watts@physics.gla.ac.uk and
the updated crib will be put on the web server.
Acquisition
Overview
Acqu Manual postscript 4
per page postscript
What to write in run log book
How to obtain a scaler dump
How to use the ACQU Graphical User Interface
(XControl)
Routine running of acquisition
What are the scaler numbers?
How to check the spectra
Very Crucial Spectra
Crucial Spectra
PiP/TOF TDC spectra
PiP/TOF QDC spectra
The tagger spectra
How to copy data to DLT tape
How to edit files on deepthought
MAMI
Overview
Safety
Opening the hall
Contact the MAMI operator
Closing the hall
beam parameters
Beam Optimization
PiP
How to relate PiP detectors to the corresponding
QDC/TDC
How to change the voltages on the PiP detectors
TOF
How to relate TOF detectors to the corresponding
QDC/TDC
How to change the voltages on the TOF detectors
Tagger
How to carry out a measurement of tagging
efficiency
Moving the Lead Glass detector in
or out of beamline
Adjusting the Lead Glass detector
into the beamline
Switching on the lead glass HV
Evacuating the tagger
Checking the vacuum
Opening the last beamline valve in
fromt of the tagger
Removing Radioactive Sources and
other Parasites from the Tagger
Handling the tagger pulser
Operating the photon TV
Tagger HV
Helium Target
Operators bible
Water target
Outline
Pictures
Automated Target Changer
Operators bible
Calculations
Calculations and simulations relevant to the experiment. [HTML]
He4(g,pp) calculations using 2N model for theta_p=60 +/- 3 degrees
@ Eg=550 MeV [postscript]
Dan Watts
Last
modified: Mon Dec 3 15:36:39 GMT 2001